
Bluetooth Dongleīus 003 Device 003: ID 05d8:4002 Ultima Electronics Corp. Premium Optical Wheel Mouse (M-BT58)īus 003 Device 004: ID 0f4d:1000 Microtune, Inc. : Bus 01.Port 1: Dev 1, Class=root_hub, Driver=ehci-pci/5p, ~]$ lsusbīus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hubīus 004 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hubīus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hubīus 003 Device 005: ID 046d:c03e Logitech, Inc. : Bus 02.Port 1: Dev 1, Class=root_hub, Driver=ehci-pci/5p, 480M |_ Port 4: Dev 5, If 0, Class=Human Interface Device, Driver=usbhid, 1.5M |_ Port 3: Dev 4, If 1, Class=, Driver=btusb, 12M |_ Port 3: Dev 4, If 0, Class=, Driver=btusb, 12M |_ Port 2: Dev 3, If 0, Class=Vendor Specific Class, Driver=, 12M |_ Port 1: Dev 2, If 0, Class=Printer, Driver=usblp, 12M : Bus 03.Port 1: Dev 1, Class=root_hub, Driver=ohci-pci/5p, 12M : Bus 04.Port 1: Dev 1, Class=root_hub, Driver=ohci-pci/5p, 12M : Bus 05.Port 1: Dev 1, Class=root_hub, Driver=xhci_hcd/2p, 480M |_ Port 1: Dev 2, If 1, Class=Human Interface Device, Driver=usbhid, 1.5M |_ Port 1: Dev 2, If 0, Class=Human Interface Device, Driver=usbhid, 1.5M : Bus 07.Port 1: Dev 1, Class=root_hub, Driver=xhci_hcd/2p, 480M As can be seen, the scanner is not on a USB3 ~]$ lsusb -t The only package in this list that is directly related to sane is 'libsane-hpaio', but that is unlikely to cause the problem, as it is not used with my hardware. Therefore, I compiled a list of packages updated since, using the command 'dnf history info 177.215 | grep -e '^]*Upgraded\>' | tr -s ' ' | cut -d ' ' -f 3 | sort | uniq >replaced_packages.txt', 177 being the last dnf transaction before this date, and 215 being the latest one. I am positive that the scanner still worked on. While I am reporting this issue for the sane-backends component, I am pretty sure that the root of the problem is somewhere else. Scanimage: open of device gt68xx:libusb:003:014 failed: Invalid argument
#MUSTEK 1200 UB PLUS USB PLUS#
IdProduct 0x4002 Artec Ultima 2000 (GT6801 based)/Lifetec LT9385/ScanMagic 1200 UB Plus ScannerīInterfaceClass 255 Vendor Specific ClassīInterfaceSubClass 255 Vendor Specific SubclassīInterfaceProtocol 255 Vendor Specific Protocolĭevice `gt68xx:libusb:003:014' is a Mustek ScanExpress 1200 UB Plus flatbed ~]$ scanimage >/dev/null Artec Ultima 2000 (GT6801 based)/Lifetec LT9385/ScanMagic 1200 UB Plus ScannerīDeviceSubClass 255 Vendor Specific SubclassīDeviceProtocol 255 Vendor Specific Protocol I just noticed that my Mustek USB scanner no longer ~]$ lsusb -d 05d8:4002 -vīus 003 Device 014: ID 05d8:4002 Ultima Electronics Corp.
